RESOURCE CONSERVATION & RECOVERY ACT

PARAMETER
METHOD
REQUIRED
VOLUME
HOLDING TIME
Corrosivity
SW 9045
100 g
Immediate
Ignitability
SW 1010
100 mL
 
Reactive Cyanide
SW 7.3.4.1
50 g
 
Reactive Sulfide
SW 7.3.3.2
50g
 
TOXICITY CHARACTERISTIC LEACHING PROCEDURE 
Total TCLP
SW 1311
1000 mL
 
TCLP (No Pest. or Herbs)
SW 1311
1000 mL
 
Total TCLP- Oily Waste
SW 1330
1000 mL
7 days
TCLP- Oily Waste (No Pest. or Herbs)
SW 1330
1000 mL
7 days
Extraction for Metals & Semivolatiles
SW 1311
250 g
7 days
Pesticides
SW 1311
1000 mL
 
Herbicides
SW 1311
1000 mL
 
Filtration Only (<0.5% Solids)
SW 1311
1000 mL
7 days
Zero Head Space Extraction
SW 1311
50 g
7 days
Zero Head Space-Oily Waste
SW 1330
50 g
7 days
Metals (All 8)
SW 1311
250 g
6 months
Individual Metals (Non-Hydride)
SW 1311
250 g
6 months
Individual Metals (Hydrides)
SW 1311
250 g
6 months
Volatiles (12 compounds)
SW 1311
50 g
14 days
Volatiles (1-3 compounds)
SW 1311
50 g
14 days
Semivolatiles (13 compounds)
SW 1311
250 g
7 days
Semivolatiles (1-3 compounds)
SW 1311
250 g
7 days

 